Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
Fisioter. Pesqui. (Online) ; 29(2): 189-195, maio-ago. 2022. graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1394344

ABSTRACT

RESUMO O objetivo deste trabalho foi comparar a fisioterapia com brinquedos com a terapia assistida por cães no desenvolvimento neuromotor de lactentes de quatro meses de idade com e sem alterações neuromotoras. Trata-se de pesquisa descritiva e observacional de caráter qualitativo, realizada com 10 lactentes, que foram avaliados pela escala motora infantil de Alberta (EMIA), divididos em grupo 1 (G1) e grupo 2 (G1) e subdivididos em grupo brinquedo (G1B e G2B) e grupo cão (G1C e G2C) para a realização das intervenções quinzenais. O questionário Affordances in the Home Environment for Motor Development - Infant Scale (AHEMD-IS) foi escolhido para avaliar as oportunidades presentes no ambiente domiciliar. A análise de dados qualitativos foi feita por meio de fotos e filmagens. A presença do cão nos grupos G1C e G2C resultou em um ambiente descontraído e divertido, interesse dos lactentes em tocar o pelo do animal, movimentos alternados de membros, contato visual, emissão de sons, evolução na interação social e sentimento de segurança. Nos grupos G1B e G2B, constatou-se diminuição da motivação, ausência de emissão de sons pelos lactentes e contato visual e interesse pelo toque restrito a brinquedos que tivessem diversas cores e sons, havendo pouca agitação e motivação para as habilidades motoras nesses grupos. Conclui-se que a presença do cão promoveu melhores resultados motores, sociais, afetivos e cognitivos. A terapia assistida por animais pode ser um método eficaz para auxiliar na fisioterapia convencional de lactentes com atraso no desenvolvimento neuropsicomotor.


RESUMEN El objetivo de este estudio fue comparar la fisioterapia con juguetes con la terapia asistida por perros en el desarrollo neuromotor de los lactantes de cuatro meses con y sin trastornos neuromotores. Se trata de una investigación cualitativa, descriptiva y observacional, realizada con 10 lactantes, quienes fueron evaluados por la escala motora infantil de Alberta (EMIA), divididos en grupo 1 (G1) y grupo 2 (G1), y subdivididos en grupo juguete (G1J y G2J) y el grupo con perro (G1P y G2P) para realizar las intervenciones quincenales. El cuestionario Affordances in the Home Environment for Motor Development - Infant Scale (AHEMD-IS) se aplicó para evaluar las oportunidades presentes en el entorno domiciliario. El análisis de los datos cualitativos se realizó a partir de fotografías y filmaciones. La presencia del perro en los grupos G1P y G2P resultó en un ambiente relajado y divertido, interés de los lactantes por tocar el pelaje del animal, alternancia de movimientos de las extremidades, contacto visual, emisión de sonidos, evolución en la interacción social y sensación de seguridad. En los grupos G1J y G2J hubo disminución de la motivación, ausencia de emisión de sonidos por parte de los lactantes y contacto visual e interés por el tacto restringido a los juguetes que tenían diferentes colores y sonidos, además de haber poca agitación y motivación para la motricidad en estos grupos. Se concluyó que la presencia del perro promovió mejores resultados motrices, sociales, afectivos y cognitivos. La terapia asistida por animales puede ser un método eficaz para ayudar en la fisioterapia convencional para los lactantes con retraso en el desarrollo neuropsicomotor.


ABSTRACT This study aimed to compare physical therapy with toys with dog-assisted therapy in the neuromotor development of 4-month-old infants with and without neuromotor alterations. This is a qualitative descriptive and observational study carried out with 10 infants, who were evaluated by the Alberta Infant Motor Scale, divided into Group 1 (G1) and Group 2 (G1), and subdivided into Toy Group (TG1 and TG2) and Dog Group (DG1 and DG2) for the performance of fortnightly interventions. By the Affordances in the Home Environment for Motor Development - Infant Scale, we assessed the opportunities present in the home environment. Qualitative data were analyzed using photos and videos. The presence of a dog in DG1 and DG2 resulted in a relaxed and fun environment, infants interested in touching the animal's fur, alternating limb movements, eye contact, sound production, increased social interaction, and feeling of security. In TG1 and TG2, decrease in motivation was observed as well as the absence of sound production and eye contact by infants, and interest in touch restricted to toys that had different colors and sounds, with little agitation and motivation for motor skills in those groups. We concluded that the dog's presence promoted better motor, social, affective, and cognitive results. Animal-assisted therapy can be an effective method to support conventional physical therapy for infants with delayed neuropsychomotor development.

2.
RGO (Porto Alegre) ; 70: e20220035, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1406486

ABSTRACT

ABSTRACT To evaluate the ability of temporary cement (TC) and gutta-percha sticks (GP) to prevent bacterial contamination of the root canal through the coronal seal after pulpectomy. Eighty artificial primary maxillary central incisors were selected and randomly divided into 2 groups: TC (n = 40) and GP (n = 40). Endodontic access, rotary instrumentation, root canal filling, and coronal sealing were performed according to group allocation. The root canal opening was seeded with S. mutans and E. faecalis. Both groups were subdivided into 5 experimental time points (24, 48, 72, 96, and 120 hours), with 8 specimens per time-point group: 5 in which both root canal filling and coronal sealing were performed (with either TC or GP) and 3 controls (coronal sealing alone, without root canal filling). All specimens were incubated in an anaerobic jar at 37°C, and bacterial contamination was assessed in a spectrophotometer. ANOVA (t-test) was used to compare contamination and the Kruskal-Wallis test to compare filling scores between the experimental groups. A significant difference was observed in sealing in the first 24 hours between GP and controls (p = 0.046). There was no significant difference in the filling pattern between canals sealed with TC versus GP. Specimens sealed with GP showed less contamination than controls in the first 24 hours. At later time points, neither GP nor TC were effective at controlling bacterial contamination; both failed to provide adequate coronal sealing.


RESUMO Avaliar a capacidade do obturador provisório (OP) e da gutapercha em bastão (GP) de prevenir a contaminação bacteriana dos condutos radiculares. Foram selecionados 80 incisivos centrais superiores decíduos artificiais que foram divididos aleatoriamente em 2 grupos: OP (n = 40) e GP (n = 40). Foi realizado acesso endodôntico, instrumentação rotatória, preenchimento do canal radicular e selamento coronário conforme os grupos. Foi feita a semeadura de S.mutans e E. faecalis na entrada do canal radicular. Ambos os grupos foram subdivididos em 5 tempos experimentais (24, 48, 72, 96 e 120 horas), com 8 espécimes por tempo experimental: 5 submetidos a preenchimento do canal radicular e selamento coronário (com OP ou GP) e 3 controles (apenas selamento coronário, sem preenchimento do canal). Todos os espécimes foram incubados em jarras de anaerobiose a 37°C e a contaminação bacteriana foi avaliada em espectrofotômetro. Utilizou-se ANOVA (teste t) para a comparação da contaminação e o teste de Kruskal-Wallis para a comparação dos escores da obturação entre os grupos experimentais. Foi observada diferença significativa no selamento nas primeiras 24 horas entre GP e controles (p = 0,046). Não houve diferença estatisticamente significativa no padrão de preenchimento entre os canais selados com OP versus GP. Os espécimes selados com GP apresentaram menor contaminação do que os controles nas primeiras 24 horas. Nos demais tempos experimentais, tanto GP quanto OP não foram eficientes no controle da contaminação bacteriana; ambos apresentaram falha no selamento coronário.

3.
RGO (Porto Alegre) ; 68: e20200033, 2020. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1136020

ABSTRACT

ABSTRACT Objective: The objective of this study was to evaluate the impact of music on anxiety in children during dental care Methods: A total of 40 children 5 to 11 years old were selected; they were randomized into 2 groups (n = 20): group 1: experimental, children were subjected to music therapy; group 2: control, children were not subjected to music therapy. We measured oxygen saturation, heart rate and levels of Corah anxiety scale and pain scale. The results for heart rate were evaluated by ANOVA. The Kruskal Wallis (Dunn) test was used to evaluate the oxygen saturation results and the Wilcoxon test for Corah anxiety and pain scores Results: There was a significant decrease in heart rate (pulse) in children who listened to music during dental treatment (p = 0.05). In the group without music, heart rate remained unchanged throughout the care (p = 0.53). There was no significant difference in oxygen saturation or Corah anxiety and pain scores in children who listened to music during dental care (p > 0.05) Conclusion: It can be concluded that music is a non-pharmacological alternative that reduces anxiety levels in children during dental treatment.


RESUMO Objetivo: O objetivo desse trabalho foi avaliar o impacto da música como redutor de ansiedade no atendimento odontológico de crianças. Métodos: Foram selecionadas 40 crianças na Clínica Infantil da Faculdade de Odontologia da PUC-Campinas com a faixa etária variando entre 5 a 11 anos de idade, distribuídas de forma randomizada em 2 grupos (n = 20): grupo 1: experimental, as crianças foram submetidas à terapia musical; grupo 2: controle, as crianças não foram submetidas à terapia musical. As crianças foram acolhidas na recepção e orientadas quanto ao procedimento. Foram feitas a aferição da saturação de oxigênio, frequência cardíaca, aplicação da escala de ansiedade de Corah e escala de dor. Os resultados da frequência cardíaca foram submetidos ao teste de ANOVA. Foram aplicados os testes não paramétricos de Kruskal Wallis (Dunn) para avaliação dos resultados da saturação de oxigênio e o teste de Wilcoxon para os resultados da escala de ansiedade de Corah e de dor. A significância foi de 5%. Resultados: Houve redução significante na frequência cardíaca (pulso) nas crianças que escutaram música durante o atendimento odontológico (p = 0.05). No grupo sem música, a frequência cardíaca manteve-se inalterada durante todo o atendimento (p = 0.53). Não houve diferença significante na saturação de oxigênio, escala de ansiedade de Corah e de dor nas crianças que escutaram ou não a música durante o atendimento odontológico (p > 0.05). Conclusão: Pode-se concluir que a música é uma alternativa não farmacológica que reduz os níveis de ansiedade na criança durante o tratamento odontológico.

4.
RGO (Porto Alegre) ; 66(2): 141-146, Apr.-June 2018. tab, graf
Article in English | LILACS | ID: biblio-956207

ABSTRACT

ABSTRACT Objective: To evaluate the sealing of cavities of dentinal occlusal caries lesions, reproduced in vitro, with flow resin compared to cavity restorations presenting healthy dentin using microhybrid composite resin. Methods: The sample consisted of 27 healthy deciduous molars where cavities of approximately 2 mm in the fossa region were performed and occlusal cleft of each tooth were sealed, impermeabilization was performed and the sample was randomly divided into 2 groups: group I underwent cariogenic challenge and occlusal sealing with resin flow. The teeth of group II were restored with microhybrid composite resin. The teeth were immersed in 5% methylene blue for 8 hours at 37° C and washed until all the dye was removed from the surface. The teeth were sectioned in the mesio-distal direction. The penetration of the dye was evaluated: 0- no penetration; 1- dye penetration up to 1/3 of the restoration; 2- dye penetration up to 2/3 of the restoration depth; 3 - penetration of dye into the pulp wall. The results were analyzed by the Biostat 4.0 program. Descriptive analysis and the mode among the examiners submitted to the Mann-Whitney test. Results: There was no significant difference in microleakage between restoration performed in healthy dentin with microhybrid composite resin or maintenance of infected dentin in primary teeth sealed with resin flow (p = 0.6035). Conclusion: It was concluded that the marginal infiltration of primary molars sealed with microhybrid composite resin and resin flow was not influenced by the removal -or not -of the carious tissue or the material used.


RESUMO Objetivo: Avaliar o selamento de cavidades de lesões de cárie oclusais em dentina, reproduzidas in vitro, com resina flow comparando com restaurações em cavidades com dentina hígida utilizando resina composta microhíbrida. Métodos: Foram selecionados 27 molares decíduos hígidos, realizadas cavidades de aproximadamente 2 mm na região de fossa e fissura da face oclusal de cada dente, impermeabilização e divisão em 2 grupos aleatoriamente: grupo I foram submetidos ao desafio cariogênico e selamento oclusal com resina flow. Os dentes do grupo II foram restaurados com resina composta microhíbrida. Os dentes foram imersos em azul de metileno a 5% durante 8 horas a 37 ° C e lavados até que todo o corante fosse removido da superfície. Os dentes foram seccionados no sentido mesio-distal. A penetração do corante foi avaliada: 0- nenhuma penetração; 1- a penetração de corante até 1/3 da restauração; 2- a penetração de corante até 2/3 da restauração profundidade; 3- penetração de corante para a parede pulpar. Os resultados foram analisados pelo programa Biostat 4.0. Foi feita análise descritiva e a moda entre os examinadores submetidas ao teste de Mann-Whitney. Resultados: Não houve diferença significante na microinfiltração entre restauração realizada em dentina hígida com resina composta microhíbrida ou a manutenção da dentina infectada em dentes decíduos selados com resina flow (p=0.6035). Conclusão: A remoção ou não do tecido cariado, assim como o material utilizado, não influenciou na infiltração marginal de molares decíduos selados com resina composta microhíbrida e resina flow.

5.
Rev. ciênc. méd., (Campinas) ; 26(2): 41-47, 14 nov. 2017. tab
Article in Portuguese | LILACS | ID: biblio-875999

ABSTRACT

Objetivo Avaliar efetividade da luz emissora de diodo, associada ao laser infravermelho, laser vermelho e luz halógena como potencializadores do clareamento dental. Métodos Foram selecionados trinta dentes bovinos hígidos que foram corados. As amostras foram divididas em: Grupo 1 controle negativo; Grupo 2 controle positivo; Grupo 3 aplicação do gel clareador; grupo 4 aplicação do gel e fotoativação com luz halógena; grupo 5 aplicação do gel e fotoativação com luz emissora de diodo; grupo 6 aplicação do gel e fotoativação com laser de baixa intensidade (vermelho) e grupo 7: aplicação do gel e fotoativação com luz emissora de diodo associada ao laser de baixa intensidade (infravermelho). Resultados Os dados obtidos foram tabulados e submetidos ao Teste de Correlação Intraclasse e mostraram correlação de replicabilidade média a boa. As médias aritméticas entre os examinadores foram submetidas ao Teste de Kruskal-Wallis, no qual foi observado que não houve diferença significante entre o controle negativo (dente não corado) e o grupo da luz emissora de diodo. Conclusão A luz emissora de diodo está indicada como potencializadora no clareamento dentário utilizando o gel clareador Whiteness HPmaxx.


Objective Evaluate the effectiveness of the light emitting diode associated with the infrared laser, red laser and halogen light as improvers of tooth whitening. Methods Thirty healthy cattle teeth were stained were selected. The samples were divided into: Group 1 negative control; Group 2 positive control; Group 3 application of bleaching gel; Group 4 gel application and curing with halogen light; Group 5 gel application and curing with light emitting diode; Group 6 gel application and low level laser light activation (red) and group 7: application of gel and curing light emitting diode associated with low level laser to (infrared). Results Data were tabulated and submitted to the intraclass correlation test and showed correlation average replicability good. The arithmetic average of the examiners were submitted to the Kruskal-Wallis test, in which it was observed that there was no significant difference between the negative control (unstained tooth) and the light-emitting diode group. Conclusion The light-emitting diode is indicated as potentiating the tooth whitening using whitening gel Whiteness HPmaxx


Subject(s)
Animals , Cattle , Tooth Bleaching , Coloring Agents , Hydrogen Peroxide
6.
Rev. Assoc. Paul. Cir. Dent ; 71(1): 36-40, Jan.Fev.Mar.2017.
Article in Portuguese | LILACS, BBO | ID: biblio-832087

ABSTRACT

Este estudo teve como objetivo avaliar a acurácia de quatro localizadores apicais eletrônicos durante o retratamento endodôntico. Quarenta pré-molares unirradiculares com apenas um canal, ápice completamente formado, foram divididos em quatro grupos e analisados: Grupo 1: Root ZX ll. Grupo 2: Mini Root. Grupo 3: Propex ll e Grupo 4: Mini Apex. Todos os elementos foram padronizados no comprimento de 22 mm, instrumentados com limas Wave One Primary (25.08), obturados e armazenados. Após um mês, foram desobturados com limas reciprocantes Wave One Primary (25.08) e, em seguida, montados em blocos de esponja vegetal, embebida em solução de cloreto de sódio a 0,9%. A acurácia eletrônica de cada elemento foi realizada, utilizando-se uma lima manual do tipo K#20, até que a mesma fosse ultrapassada pelo forame e recuada até o comprimento real do dente, onde, então, as medidas de cada elemento eram anotadas. Todas as medidas obtidas de cada grupo passaram por análise estatística. Não houve diferença estatisticamente significante entre os localizadores apicais eletrônicos analisados, quando utilizados durante o retratamento endodôntico, sendo possível concluir que, os quatro modelos de localizadores apicais analisados mostraram-se eficientes durante o retratamento endodôntico, dentro dos limites estabelecidos, não havendo diferença entre eles.


This study aimed to evaluate the accuracy of four electronic apex locators during endodontic retreatment. Forty single-rooted premolars, with a root canal, with fully formed apex, were divided into four groups and analyzed: Group 1: Root ZX II. Group 2: Mini Root. Group 3: Propex II and Group 4: Mini Apex. All elements have been standardized in the length of 22 mm, instrumented with Wave One Primary (25.08) files, sealed and stored. After a month, the desobturation with reciprocating Wave One Primaty (25.08) files off and then assembled into blocks vegetable sponge, soaked in 0.9% sodium chloride solution. Electronic accuracy of each element was performed using a manual file type K#20, until it was overtaken by the foramen and retracted to the actual length of the tooth, which then measures each element were noted. All measurements obtained from each group passed by statistical analysis. There was no statistically significant difference between the electronic apex locators analyzed when used during endodontic retreatment it is possible to conclude that the four models analyzed apex locators were effective during endodontic retreatment wirhin the established timits, there is no difference between them.


Subject(s)
Endodontics , Retreatment , Tooth Apex
7.
Rev. Assoc. Paul. Cir. Dent ; 70(2): 181-186, abr.-jun. 2016. tab, ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-797070

ABSTRACT

Objetivo: avaliar ex vivo a quantidade de guta-percha remanescente no retratamento de canal de dentes pré-molares inferiores com único canal utilizando o sistema WaveOne Gold em comparação com o sistema de retratamento ProTaper R. Materiais e métodos: foram selecionados 52 pré-molares inferiores humanos extraídos, distribuídos aleatoriamente em 2 grupos (n=26), em função das técnicas de retratamento: sistema WaveOne Gold (grupo 1) e sistema de retratamento ProTaper R (grupo 2). Após os canais radiculares serem instrumentados e obturados com guta--percha, foram submetidos à de sobturação e ao procedimento de retratamento. Os dentes foram seccionados confeccionando uma canaleta nas faces proximais dos dentes obtendo-se duas hemi--secções radiculares, expondo, portanto, a luz do canal preparado. Todas as amostras foram codificada se fotografadas por máquina Cânon A640 acoplada ao microscópio Zeiss, com aumento de 5 vezes. As fotos foram transportadas para o programa de software Image Tool 3.0. Foi feita medição das áreas de remanescentes de material obturador no interior do canal e a medição da área total do interior do canal através das imagens da secção no computador. As medidas foram comparadas em relação a cada sistema utilizando o programa BioEstat 4.0 (teste de Mann-Whitney). Resultados:A menor porcentagem de material obturador remanescente ocorreu no sistema ProTaper Rcom diferenças significantes em relação ao sistema WaveOne Gold (p<0.01). Conclusão: o sistemaProTaper R foi mais eficaz na remoção de guta-percha em comparação com o sistema WaveOne Gold, entretanto nenhum dos sistemas removeram totalmente o material obturador do canal.


Objective: This ex vivo research study aims to evaluate ex vivo the amount of remaining gutta -perchaduring canal retreatment of lower premolars single-rooted using WaveOne Gold system compared with Protaper R system. Materials and methods: 52 mandibular premolars were selected and randoml y divided into 2 groups (n = 26), according to the retreatment techniques, which are: WaveOne Gold system(group 1) and ProTaper R system (group 2). After the root canals were instrumented and filled withgutta-percha, they underwent removal procedure. After retreatment procedure, the teeth were sectioned in the proximal surfaces resulting in two hemi-sections exposing the interior of the root canal. Allsamples were coded and photographed by A640 Canon machine attached to the microscope Zeiss withzoom in 5 times, and the photos were transported to the Image Tool 3.0. software. The evaluation wasdone by measurement of areas of remaining filling material and the total area of the interior of root canal through the images on the computer. The measurements were compared for each system using Bio-Estat 4.0 program and Mann-Whitney test. Results: The smallest percentage of remaining gutta-perchaoccurred in ProTaper Retreatment system with significant differences from the WaveOne Gold system(p <0.01).Conclusion: ProTaper R system was more effective in removing gutta-percha compared withWaveOne Gold system. However none of the both systems completely removed the filling material.


Subject(s)
Endodontics/methods , Retreatment/methods , Retreatment
8.
Rev. ciênc. méd., (Campinas) ; 25(1): 41-47, jan.-abr. 2016. tab, ilus
Article in Portuguese | LILACS | ID: biblio-833190

ABSTRACT

Objetivo Avaliar se o fotopolimerizador de uso odontológico (luz emissora de diodo) aplicado por 20 segundos sobre o cimento de ionômero de vidro convencional pode acelerar a presa química deste material. Métodos Os cimentos ionoméricos utilizados foram o Vidrion R (SS White, Rio de Janeiro) e o Ketac Molar (3M, Espe, Alemanha). Foram confeccionados quarenta corpos de prova divididos em quatro grupos (n=10): G1: Vidrion R sem fonte de luz; G2: Vidrion R ativadas por luz durante 20 segundos; G3: Ketac Molar sem fonte de luz; G4: amostras de Ketac Molar ativadas por luz durante 20 segundos. A espatulação do ionômero foi em quarenta segundos desde o início do processo até a perda do brilho. A fonte de luz foi o aparelho Optilight Max (Gnatus, São Paulo) com potência de luz de 1200mW/cm² e comprimento de onda de 450nm. Os resultados foram analisados no Programa Biostat (Analyst Soft, Walnut, Califórnia, Estados Unidos) versão 4.0, realizada a análise descritiva e o teste de Kruskal Wallis (Student-Newman-Keuls). Resultados A utilizaçãoda luz nos cimentos ionoméricos convencionais Vidrion R e Ketac Molar acarretou redução significativa no tempo gasto para a presa química destes materiais (p<0.01). Não houve diferença entre o tempo gasto para presa química com ou sem a utilização da fonte de luz, quando comparados os cimentos ionoméricos Vidrion e Ketac (p>0.05). Conclusão Autilização da fonte de luz emissora de diodo está indicada para acelerar a presa química inicial dos cimentos ionoméricos convencionais reduzindo o tempo operatório e favorecendo o tratamento em odontopediatria.


Objective To assess whether a dental light curing unit (light emission diode) used for 20 seconds on conventional glass-ionomer cement can accelerate chemical setting of the material. Methods The glass-ionomer cements used were Vidrion R (SS White, Rio de Janeiro, Brazil) and Ketac Molar (3M, Espe, Germany). Forty test specimens were fabricated and divided into 4 groups (n=10): G1: R Vidrion samples without using the light source; G2: Vidrion R samples light activated for 20 seconds; G3: Ketac Molar samples without using the light source; G4: Ketac Molar samples light activated for 20 seconds. In all groups the ionomer was spatulated for 40 seconds. The time elapsed from the beginning of the spatulation to the loss of gloss was recorded in seconds. The light source device was the Optilight Max (Gnatus, São Paulo, Brazil) with light output of 1200mW/cm² and a wavelength of 450nm. The software Biostat version 4.0 (Analyst Soft, Walnut, California) analyzed the results. Descriptive analysis was performed, and the Kruskal Wallis test was used (Student-Newman-Keuls). Results The use of light on conventional glass ionomer cements Vidrion R and Ketac Molar significantly reduced the time required for the chemical setting of these materials (p<0.01). The chemical setting time of the glass-ionomer cements Vidrion and Ketak did not differ with or without the light source (p>0.05). Conclusion The use of a light emission diode is indicated to accelerate the initial chemical setting of conventional glass-ionomer cements, reducing the operative time and improving treatment in pediatric dentistry


Subject(s)
Catalyzer , Curing Lights, Dental , Glass Ionomer Cements
9.
Rev. Assoc. Paul. Cir. Dent ; 70(1): 70-75, jan.-mar. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-797056

ABSTRACT

Objetivo: avaliar a influencia da contaminação cavitária na adaptação marginal das restauraçõesde resina composta e a associação da lisozima ao sistema adesivo. Materiais e Métodos:Foram selecionados 40 terceiros molares permanentes e confeccionados preparos cavitários classeV com pontas diamantadas cilíndricas 1090 (4 mm de largura, 6 mm de comprimento e 1,5 mmde profundidade). Todos os dentes foram esterilizados e divididos aleatoriamente em 4 grupos(n=10): G1: sistema adesivo (SA) e restauração com resina composta (RC); G2: cavidadescontaminadas com 10 μl de Streptococcus mutans (0,5 de Mc Farland), SA e RC; G3:sistema adesivo associado com lisozima (ADL) e RC e G4: cavidades contaminadas com 10 μlde Streptococcus Mutans (0,5 de Mc Farland), ADL e RC. A lisozima foi adicionada ao SA com ummicrobrush embebido no SA e na lisozima em pó. Os dentes foram impermeabilizados e imersosem azul de metileno por 4 horas a 37ºC. Os dentes foram seccionados e fotografados. Resultados:A avaliação da microinfiltração foi feita por dois avaliadores utilizando o Programa Tpsdig. Paraavaliar a calibração entre os examinadores, foi utilizado o teste de Correlação de Pearson. As médiasdas porcentagens de fendas e bolhas foram submetidas ao teste de Kruskal Wallis com 5% designificância. Conclusão: a contaminação cavitária com Streptococcus mutans acarretou na formaçãode fendas entre a resina composta e as margens cavitárias. A lisozima associada ao sistemaadesivo não influenciou na formação de fendas e bolhas nas restaurações de resina composta.


Objective: evaluate the influence of cavity contamination on marginal adaptation of compositerestorations and the association of lysozyme to the adhesive system. Materials and Methods:Were selected 40 permanent third molars and made cavity preparations class V with cylindricaldiamond burs 1090 (4 mm wide, 6 mm long and 2 mm deep). All teeth were sterilized and randomlydivided into 4 groups (n = 10): G1: adhesive system (SA) and restoration with compositeresin (CR); G2: cavity contaminated with 10 μl of Streptococcus mutans (0.5 McFarland), SA andRC; G3: adhesive system associated with lysozyme (ADL) and RC and G4: cavity contaminated with10 μl of Streptococcus mutans (0.5 Mc Farland), ADL and RC. Lysozyme was added to the SA witha microbrush embedded in the SA and powdered lysozyme. The teeth were sealed and immersedin a methylene blue for 4 hours at 37 ° C. The teeth were sectioned and photographed. Results:The evaluation of microleakage was made by two reviewers using the Tpsdig Program. To assessthe calibration of examiners, we used the Pearson correlation test. The mean percentages of cracksand bubbles were submitted to Kruskal Wallis test at 5% significance level. Conclusion: the cavityStreptococcus mutans contamination resulted in the formation of cracks between the compositeresin and the cavity margins. Lysozyme associated with the adhesive system did not influence theformation of cracks and bubbles in the composite restorations.


Subject(s)
Humans , Male , Female , Dentin-Bonding Agents/analysis , Dentin-Bonding Agents/adverse effects , Dentin-Bonding Agents/therapeutic use , Dental Leakage/complications , Streptococcus mutans/classification , Streptococcus mutans/growth & development , Streptococcus mutans/virology
10.
Rev. Assoc. Paul. Cir. Dent ; 70(1): 82-85, jan.-mar. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-797058

ABSTRACT

Objetivo: avaliar a eficácia de três diferentes métodos de higienização sobre cepas de S.mutans dos protetores bucais feitos sob medida: dentifrício fluoretado, detergente neutro eclorexidina. Materiais e Métodos: foram confeccionados 30 protetores bucais feitos sob medida com placas de silicone de 3 mm que foram contaminados em meio de sobrevivência BHI (BrainHeart Infusion) suplementado com 1% de glicose e sacarose e 0,5% de extrato de levedura e incubados em jarra de anaerobiose a 37°C em estufa bacteriológica por 15 dias. O meio foi renovado a cada 24 horas. Após a contaminação, foi feita a coleta dos protetores bucais, esfregaço e plaqueamento na superfície do meio de cultura mitis salivarius com bacitracina. Os protetores foram higienizados com escova dental, com três diferentes meios de higienização:dentifrício fluoretado, detergente neutro e clorexidina e, após a higienização foram submetidos a uma nova coleta, esfregaço e plaqueamento. Após incubação, foi feita a contagem do total de bactérias viáveis. Os resultados obtidos foram submetidos à análise estatística e ao teste não paramétrico de Wilcoxon. Resultados: houve redução microbiana significativa da contagem deS. mutans utilizando clorexidina e detergente (p<0.05). Não houve diferença significante na contagem antes e depois utilizando o dentifrício (p>0.05). Conclusão: a clorexidina e o detergente podem ser utilizados para desinfecção dos protetores bucais.


Objective: The effect of three different cleaning methods on custom-made mouth guards’strains of S. mutans: fluoridated tooth paste, neutral detergent and chlorhexidine. Materials and Methods: it were made 30 mouthguards custom-made with 3mm silicone slabs that have been subjected to a microbiological processing in supplemented BHI (Brain Heart Infusion). They were in cubated in anaerobic jar at 37 ° bacteriological green house for 15 days, changing the medium every 24 hours. After the contamination, samples were drawn and it was made the collection, smear and plating on surface of the culture medium mitis salivarius with bacitracin and then they were cleaned with tooth brush with three different modes of cleaning: chlorhexidine, neutral detergent and fluoridated tooth paste. After incubation, the count was made of total viable bacteria. The results were statistically analyzed by the Wilcoxon non-parametric test. Results: there wasa significant reduction in microbial counts before and after using chlorhexidine and detergent (p<0.05). There wasn’t significant difference in the count before and after using the tooth paste(p>0.05). Conclusion: chlorhexidine and detergent can be used for disinfection of mouth guards


Subject(s)
Humans , Male , Female , Mouth Protectors , Mouth Protectors/adverse effects , Streptococcus mutans/classification , Streptococcus mutans/growth & development , Streptococcus mutans/chemistry
11.
Pesqui. bras. odontopediatria clín. integr ; 16(1): 299-305, jan.-dez. 2016. tab
Article in English | LILACS, BBO | ID: biblio-912841

ABSTRACT

Objective:To assess root canal morphological results and cleaning capacity in deciduous teeth instrumented with a reciprocating system.Material and Methods:15 deciduous molars and a total of 24 canals were selected for the study. Nine teeth(13 canals) were selected at random for microbiological analysis and 6 teeth (11 canals) were used for tomographic analysis of morphology. The roots used for the microbiological assessment were contaminated with standard strains of Enterococcus faecalis. All roots were instrumented using the WaveOne System with a Small (21:06) 21mm file and an X-Smart plus motor. Tomography was conducted with an I-CAT machine before and after instrumentation with the objective of analyzing the WaveOne System's shaping capacity. Statistics: Biostat 4.0 software was used to analyze results. The microbiological results (log10) and tomographic results (pixels) were analyzed using descriptive statistics and the Wilcoxon test.Results:There was a significant reduction in Enterococcus faecalis colony-forming units after instrumentation of the root canal systems of deciduous molars using the WaveOne system (p=0.0033) and significant enlargement of the root canal systems was observed after instrumentation (p=0.047), while morphology was maintained. Conclusion:The WaveOne System, using the Small file was effective for disinfection of the root canal systems of deciduous molars


Subject(s)
Humans , Dental Pulp Cavity/microbiology , Endodontics , Molar/microbiology , Tooth, Deciduous/microbiology , Brazil , Cone-Beam Computed Tomography/instrumentation , Statistics, Nonparametric
12.
RGO (Porto Alegre) ; 63(2): 187-194, Apr.-June 2015. tab, ilus
Article in English | LILACS | ID: lil-755129

ABSTRACT

OBJECTIVE:

The purpose of this research was to follow the radiolucent area (pixels) in the furcation area and the behavior of the endodontically treated deciduous molars with different simplified echniques.

METHODS:

The treatments were performed without the duct instrumentation using relative isolation and two drugs were applied, as follows: G1: Guedes-Pinto paste (GP) and G2: CTZ paste (CTZ) for the pulp chamber filling. The radiolucent areas in the furcation region of deciduous molars were obtained from previous x-rays, after 6 and 12 months of the endodontic treatment and was analysed by l Image Tool 3.0 by two blinded examiners. In order to analyse the calibration between the examiners, Kappa test was used and for comparison of the initial radiographic image, analysis of variance was used after 6 and 12 months of each group and Tukey spost-hoc test. T-Student test was used for comparison between groups.

RESULTS:

There was a reduction of radiolucent area after 6 (p<0.01) and 12 months (p<0.01) in the teeth treated with CTZ paste. In the teeth treated with PG there was not reduction of radiolucent area after 12 months. (p= 0,09).

CONCLUSION:

Although the clinical signs were similar in both groups after 12 months of follow up, only teeth treated with CTZ showed reduction of radiolucent area in the furca area after 6 and 12 months.

.

OBJETIVO:

A proposta da pesquisa foi acompanhar a area radiolúcida (pixels) na região de furca e a resposta clínica de molares decíduos tratados endodonticamente com diferentes tecnicas simplificadas.

MÉTODOS:

Os tratamentos foram executados sem instrumentação dos condutos e com isolamento relativo, utilizando-se dois medicamentos: G1:Pasta Guedes-Pinto (PG) e G2: Pasta CTZ (CTZ) no preenchimento da câmara pulpar . As áreas radiolúcidas na região de furca dos molares decíduos obtidas das radiografias antes, após 6 meses e 12 meses do tratamento endodôntico foram analisadas no programa Image Tool 3.0 por 2 examinadores cegos. Para analisar a calibração entre os examinadores foi utilizado o teste Kappa e para comparação da imagem radiográfica inicial, após 6 e 12 meses de cada grupo foi utilizado a Análise de Variância e o teste complementar de Tukey. O teste T Student foi usado para comparação entre os grupos.

RESULTADOS:

A redução da área radiolúcida inicial após 6 (p<0,01) e 12 meses (p<0,01) foi observada somente com o uso da pasta CTZ. O emprego da pasta Guedes não resultou em diminuição da área radiolúcida após 12 meses de acompanhamento (p=0,09).

CONCLUSÃO:

A resposta clínica foi semelhante em ambos os grupos, porém apenas os dentes tratados com a pasta CTZ apresentaram redução da área radiolúcida na região da furca após 6 e 12 meses de acompanhamento.

.

13.
Rev. Assoc. Paul. Cir. Dent ; 69(4): 421-425, 2015. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-778746

ABSTRACT

Objetivo: avaliar clinicamente a eficácia da Terapia de Laser de Baixa Potência (TLBP) no alívio da dor após a instalação do aparelho ortodôntico e primeiro arco. Materiais e Métodos: 90 voluntários receberam aparelho fixo e colocação do primeiro arco ortodôntico. Foram randomicamente divididos em três grupos: Grupo 1- Controle (n=30), Grupo 2 - Placebo (n=30) e Grupo 3 - Laser (n=30). Foi realizada a TLBP infravermelho (810 nm) com 100 mW de potência e dose de 6 J/cm2 divididas em quatro aplicações por dente. A dor foi avaliada utilizando Escala Visual Analógica (EVA). Os dados obtidos foram submetidos à análise estatística por meio de teste de Kruskal- Wallis (α=0,05). Resultados: Em todos os grupos analisados a dor iniciou-se após 2 horas, houve um pico de dor entre 12 horas e 48 horas e sua diminuição ocorreu em sete dias. O Grupo 3 (Laser) apresentou todos os valores de dor menores em relação aos valores observados nos outros grupos. Houve diferença estatisticamente significante (p<0,05) da dor pós-operatória entre 12 e 48 horas (momento de pico de dor) para o grupo 3 em relação aos grupos 1 e 2. Conclusão: A TLBP mostrou-se eficiente para a redução da dor após a colocação do aparelho fixo e primeiro arco ortodôntico...


Objective: The aim of this study was to clinically evaluate Low Level Laser Therapy (LLLT) as a method of reducing pain after the first orthodontic archwire placement. Materials and Methods: 90 volunteers received metal braces and the first archwire. They were randomly distributed over three different treatment groups: Group 1- (n=30) Control, patients did not received any LLLT; Group 2- (n=30) Placebo, the LLLT was simulated, the laser was turned off; Group 3- (n=30) Laser patients received LLLT, infra-red with 810 nm wave length and 100 mW power, and it was used 6 J/cm2 as total dose per tooth, divided into four times of 1.5 J/cm2 per 12 seconds per point. Pain intensity experienced was evaluated by a Visual Analogue Scale. Data were tabulated and analyzed through Biostat 4.0 software. Means and standard deviations were calculated and a Kruskal-Wallis statics test was performed (Dunn’s method) (α=0.05). Results: It was possible to observe that the pain started 2 hours after treatment was initiated in the three groups. Higher pain levels occurred between 12 and 48 hours, and pain reduction occurred in 7 days. Group 3 (Laser) presented lower pain data values than the other groups. There was a statistically significant difference (p<0.05) among post operating pain in times T3, T4 and T5 between group 3 and groups 1 and 2. Conclusion: LLLT reduced the pain after orthodontics braces and archwires placement...


Subject(s)
Humans , Dental Arch , Orthodontics , Low-Level Light Therapy/methods , Low-Level Light Therapy
14.
Braz. dent. j ; 25(6): 502-507, Nov-Dec/2014. tab
Article in English | LILACS | ID: lil-732258

ABSTRACT

This aim of this study was to assess the ability of manual or rotary instrumentation associated with photodynamic therapy (PDT) to reduce Enterococcus faecalis using three combinations of light/photosensitizers: toluidine blue O/laser, fuchsin/halogen light and fuchsin/LED. Twenty deciduous molars were selected and contaminated with Enterococcus faecalis (McFarland 0.5 scale). Working length determination was performed by visual method. The teeth were randomly divided into two groups: G1 (n=10): manual instrumentation (Kerr-type files) and G2 (n=10): rotary instrumentation (ProTaper system). The bacteria were collected three times using sterile paper cones compatible with the anatomic diameter of the root canal for 30 s before and after instrumentation and after PDT. The samples were diluted in peptone water, seeded on blood agar plates and incubated in an oven at 37 °C for colony-forming units counting. The decrease of E. faecalis counts after instrumentation and after PDT was compared using the Wilcoxon test, t-test and Kruskal Wallis test. A significant reduction of E. faecalis occurred after manual and rotary instrumentation and after PDT using the three combinations of light/photosensitizer (p<0.05). It may be concluded that both rotary and manual instrumentation reduced E. faecalis. Fuchsin with halogen light or LED irradiation and toluidine blue O with laser irradiation can be used to reduce E. faecalis in root canals of primary molars. PDT can be used as an adjuvant to conventional endodontic treatment.


O objetivo do presente estudo foi avaliar a redução de Enterococcus faecalis após instrumentação manual ou rotatória associada à terapia fotodinâmica (PDT) utilizando 3 combinações luz/fotossensibilizante: azul de toluidina O/laser, fucsina/luz halógena e fucsina/LED. Foram selecionados 20 molares decíduos que foram contaminados com Enterococcus faecalis (escala 0,5 de McFarland). A odontometria foi feita através do método visual. Os dentes foram divididos aleatoriamente em dois grupos: G1 (n=10): instrumentação manual (limas tipo Kerr) e G2 (n=10): instrumentação rotatória (sistema ProTaper). Foram realizadas coletas com cone de papel estéril compatível com o diâmetro anatômico do canal durante 30 s antes e após a instrumentação e a PDT. As amostras foram diluídas em água peptonada, semeadas em placas de agar-sangue e incubadas em estufa a 37 °C para contagem das unidades formadoras de colônias. As comparações antes da redução de E. faecalis após a instrumentação e após a realização da PDT foram realizadas pelo teste de Wilcoxon, teste t e Kruskal Wallis. Houve redução significante de E. faecalis após a instrumentação manual ou rotatória e após realização da PDT com as três combinações de luz/fotossensibilizante (p<0,05). Pode-se concluir que a instrumentação rotatória e manual acarretou a redução de E. faecalis. A fucsina irradiada com luz halógena ou led e o azul de toluidina irradiado com laser podem ser utilizados para redução de E. faecalis do sistema de canais radiculares de molares decíduos. A terapia fotodinâmica pode ser utilizada como coadjuvante ao tratamento endodôntico convencional.


Subject(s)
Animals , Mice , Acid Phosphatase/biosynthesis , Cathepsin B/biosynthesis , Leucine/analogs & derivatives , Leupeptins/pharmacology , Melanoma, Experimental/enzymology , Oligopeptides/pharmacology , Pepstatins/pharmacology , Peptide Hydrolases/biosynthesis , Protease Inhibitors/pharmacology , Enzyme Induction , Leucine/pharmacology , Subcellular Fractions/drug effects , Subcellular Fractions/enzymology , Tumor Cells, Cultured
15.
Article in Portuguese | LILACS | ID: lil-724212

ABSTRACT

Objetivo: viabilizar a utilização de dentes decíduos artificiais com polpa e condutos radiculares em pesquisas ôin vitroõ com o uso do localizador apical Root ZX II. Método: foram selecionados 20 molares decíduos artificiais que apresentavam três condutos radiculares e não apresentavam trincas, fraturas ou defeitos de fabricação. Foi feita abertura coronária, acesso aos condutos, patência foraminal e mensuração dos canais radiculares por meio de método visual e eletrônico. A mensuração no método visual (G1- controle) foi realizada introduzindo a lima no ponto da cúspide de referência até a lima atingir o forame apical. No método eletrônico (G2- experimental), os dentes foram inseridos em alginato e a lima inserida no canal radicular até o localizador indicar o ápice. As mensurações foram realizadas em triplicata. As médias das medidas em milímetros foram submetidas ao teste de correlação de Pearson no programa Biostat 2.0 com valor de significância de 5%. Resultados: as medidas observadas pelo método eletrônico apresentaram correlação com os resultados obtidos pelo método visual (r Pearson = 0,9490; p = 0,0000). Conclusão: os dentes decíduos artificiais podem ser utilizados em pesquisas ôin vitroõ com o localizador apical Root ZX II...


Objective: To allow the use of artificial primary teeth with pulp and root canals for in vitro studies with the Root ZX II electronic apex locator.Method: Twenty artificial primary molars with three root canals and no cracks, fractures or fabrication defects were selected. After coronal opening, access to the canals was gained, foramen patency waschecked and direct and electronic working length determination was performed. For direct visual working length determination (Group 1 ?control), the file was introduced into the canal from the reference cusp until its tip was visible at the apical foramen. For the electronic working length determination (Group 2 ? experimental), the teeth were embedded in alginate and the file was introduced into the canal until the electronica locator indicated the apex. The measurements were made in triplicate. The means (in mm) were subjected to Pearson?s correlation coefficient test using the Biostat 2.0 software. The significance level was set at 5%.Results: The electronic measurements correlated with the direct visual measurements (r=0.9490; p=0.0000).Conclusion: Artificial primary teeth can be used for in vitro studies with the Root ZX II electronic apex locator...


Subject(s)
Humans , Tooth, Artificial , Tooth, Deciduous/physiology , In Vitro Techniques , Root Canal Therapy , Fujita-Pearson Scale , Odontometry/methods , Radiography, Dental/instrumentation
16.
Braz. dent. j ; 24(1): 68-73, 2013. tab, graf
Article in English | LILACS | ID: lil-671356

ABSTRACT

Dental materials with antibacterial properties can prevent the harmful effects caused by oral cariogenic bacteria. This double-blind controlled clinical trial evaluated the performance of a glass ionomer cement (GIC) added with antibiotics for sealing infected dentin in atraumatic restorations of primary molars. The study enrolled 45 children (45 teeth) between 5 and 8 years of age, of both genders, divided into two groups: GC (n=22), where cavities were lined with a conventional GIC (Vidrion F) and GA (n=23), with cavities lined with Vidrion F added with 1% each of metronidazole, ciprofloxacin and cefaclor antibiotic. Both groups were restored with Ketac Molar Easymix. Molars with carious lesions on the inner half of dentin without clinical or radiographic pulp damage were selected. Patients were evaluated clinically (pain, fistulas or mobility) and radiographically (area of caries, periapical region and furcation) after 1, 3, 6 and 12 months. For statistical analysis, chi-squared or Fisher's exact tests were used with a 5% significance level. GA (82.6-95.7%) had better results than GC (12.5-36.4%) in all evaluations (p<0.05) and the difference in the success rate was 46.2-72.5% higher for GA. The use of the antibiotic-containing GIC liner on infected dentin proved satisfactory when applied in deciduous teeth.


Os materiais dentários com propriedades antibacterianas podem proteger os efeitos nocivos causados por bactérias cariogênicas. Este ensaio clínico controlado duplo-cego avaliou o desempenho do cimento de ionômero de vidro (CIV) associado à antibióticos no selamento da dentina infectada em restaurações atraumáticas de molares decíduos. O estudo envolveu 45 crianças (45 dentes) entre 5 e 8 anos de idade, de ambos os sexos, divididos em dois grupos: GC (n=22), onde as cavidades foram forradas com CIV convencional (Vidrion F) e GA (n=23), onde as cavidades foram forradas com Vidrion F contendo 1% de cada um dos antibióticos metronidazole, ciprofloxacina e cefaclor. Ambos os grupos foram restaurados com Ketac Molar Easymix. Molares com lesões de cárie na metade interna da dentina, sem danos pulpares clínicos ou radiográficos foram selecionados. Os pacientes foram avaliados clinicamente (presença de dor, fístulas ou mobilidade) e radiograficamente (área de cárie, região periapical e de furca dos dentes), após 1, 3, 6 e 12 meses. Para a análise estatística o Qui-quadrado ou Exato de Fisher foram utilizados com 5,0% de significância. GA (82,6-95,7%) obteve melhores resultados do que GC (12,5-36,4%) em todas as avaliações (p<0,05) e a diferença na taxa de sucesso foi de 46,2-72,5% maior para GA. O uso do CIV com antibióticos no forramento da dentina infectada foi satisfatório em dentes decíduos.


Subject(s)
Child , Child, Preschool , Female , Humans , Male , Anti-Bacterial Agents/administration & dosage , Cariostatic Agents/chemistry , Dental Cavity Lining , Dental Atraumatic Restorative Treatment/methods , Dental Caries/therapy , Dentin/pathology , Glass Ionomer Cements/therapeutic use , Chi-Square Distribution , Cariostatic Agents/therapeutic use , Cefaclor/administration & dosage , Ciprofloxacin/administration & dosage , Double-Blind Method , Dentin/microbiology , Glass Ionomer Cements/chemistry , Metronidazole/administration & dosage , Tooth, Deciduous
17.
Rev. ciênc. méd., (Campinas) ; 22(2): 87-94, 2013. tab
Article in English | LILACS | ID: lil-724315

ABSTRACT

Objective: The aim of this study to count anaerobic bacteria before and after the use of dental equipment and to study the influence of chlorhexidine on the dental unit reservoir water. Methods: Sterile swabs were used to collect bacterial samples from the cuspidor, lights, syringes, low-and high speed handpieces and dental chairs (arms and backrest) before and after the placement of barriers. Blood agar plates were placed on the patient's and dentist's forehead and by the patient's nose and shoulder and exposed to aerosoils without (group 1) and with 0,5% (group 2) and 1,0% (group 3) chlorhexidine generated by the high speed handpiece. Ten aerosol samples were collected for each group. A sample of 1mL of the dental unit reservoir water was collected before and after the use of the high speed handpiece. The anaerobic bacterial counts were compared by the Wilcoxon and Kruskal-Wallis tests. Results: The contamination of the high speed handpiece (p=0,0431) and cuspidor (p=0,0117) increased significantly after use. Contamination in the dental unit reservoir water also increased significantly after use of the high speed handpiece. The most contaminated area was the patient's nose. Conclusion: The addition of 0,5% and 1,0% chlorhexidine in the dental office sifnificantly.


ObjetivoO objetivo deste estudo foi quantificar as bactérias anaeróbicas, antes e após o uso deequipamentos odontológicos e estudar a influência da clorexidina na água doreservatório.MétodosOs seguintes itens foram avaliados: cuspideira, luzes, seringas, baixa e alta rotação,braço da cadeira e do encosto com coleções realizadas antes e após a colocação debarreiras. A contaminação microbiana causada pelos aerossóis de alta rotação tambémfoi avaliada: Grupo 1 (controle): (100%) de água no reservatório; Grupo 2: água noreservatório contendo 0,5% de clorexidina, Grupo 3: água no reservatório contendo1,0% de clorexidina. Dez amostras de aerossol foram recolhidos a partir de cadagrupo: placas de ágar-sangue foram colocadas na testa do paciente e do dentista e nonariz e ombro do paciente. Amostra de 1mL a partir do conteúdo da água no reservatóriofoi medida antes e após a utilização de alta rotação. Comparações entre bactériasanaeróbias foram feitas com o uso de Wilcoxon e Kruskal-Wallis teste estatístico.ResultadosVerificou-se um aumento significativo na contaminação antes e após o procedimentoutilizando alta rotação (p=0,0431) e na cuspideira (p=0,0117). Foi possível observarum aumento significativo de contaminação microbiana na água do reservatório, apósa sua utilização. O nariz do paciente era a área mais afetada.ConclusãoA adição de 0,5% e 1,0% de clorexidina no reservatório representa uma reduçãosignificativa de contaminação microbiana gerado no ambiente de um consultório odontológico.


Subject(s)
Bacteria, Anaerobic/growth & development , Environmental Pollution , Chlorhexidine/therapeutic use , Dental Equipment/microbiology
18.
RSBO (Impr.) ; 9(3): 238-244, Jul.-Sep. 2012. ilus, tab
Article in English | LILACS | ID: lil-748119

ABSTRACT

Introduction: The rotary instrumentation provides shorter instrumentation time with greater comfort for the patient but few studies have been conducted on primary teeth. Objective: his study compared the cleaning ability and instrumentation time between manual and rotary techniques in deciduous molars. Material and methods: a total of 15 molars were selected, submitted to coronal opening and root canal filled with India ink. After 48 hours, the teeth were divided into three groups: G1 - manual instrumentation with K files, G2 - rotary system Endowave, and G3 - rotary system ProTaper. After instrumentation, the teeth were sectioned and three blinded examiners evaluated the root canal cleaning. The mode of scores of examiners was analyzed by the Kruskal-Wallis test. The instrumentation time was recorded and the results were statistically analyzed by ANOVA.Results: the ProTaper system presented shorter instrumentation time compared to manual instrumentation (p = 0.0339). Endowave system did not present statistically significant difference in the instrumentation time compared to the other groups. There were no significant differences between groups concerning the ability of root canal cleaning (p = 0.6188). Conclusion: ProTaper system revealed shorter treatment time and similar cleaning ability compared to the other techniques, thus being indicated for deciduous teeth.

19.
RSBO (Impr.) ; 9(1): 11-15, Jan.-Mar. 2012. graf, tab
Article in English | LILACS | ID: lil-748082

ABSTRACT

Introduction: There are few researches in literature that mention the use of the apex locator in deciduous teeth and working length is obtained through radiographies. Objective: The purpose of this research was to compare the radiographic and the electronic method to obtain the working length in deciduous molars. Material and methods: Twelve molar teeth were used. The specimens in the visual method had their root length measured through the passive insertion of a 10 K-file with a silicone stop within root canal until its tip was seen at the apical foramen. The working length was measured through radiographs or using the apex locator Root ZX II. The mean between the examiners was submitted to the variance analysis (ANOVA). Results: Statistically significant differences were found between the visual method and the radiographic method (p < 0.001). There was no significant difference between the working length measurements in visual method and those obtained with the apex locator (p = 0.1319). Conclusion: The apex locator is indicated as a clinical implementation for endodontic treatment in primary teeth.

20.
J. appl. oral sci ; 20(1): 32-37, Jan.-Feb. 2012. ilus, tab
Article in English | LILACS | ID: lil-618150

ABSTRACT

OBJECTIVES: This study evaluated in vitro the efficiency of Aloe vera and propolis dentifrice on reducing the contamination of toothbrush bristles by a standard strain of Streptococcus mutans (ATCC 25175; SM), after toothbrushing. MATERIAL AND METHODS: Fifteen sterile toothbrushes were randomly divided into 5 toothbrushing groups: I (negative control): without dentifrice; II: with fluoridated dentifrice; III: with triclosan and gantrez dentifrice; IV (positive control): without dentifrice and irrigation with 10 mL of 0.12 percent chlorhexidine gluconate; V: with Aloe vera and propolis dentifrice. In each group, 1 sterile bovine tooth was brushed for 1 min, where the toothbrush bristles were contaminated with 25 µL of SM. After toothbrushing, the bristles were stored in individual test tubes with 3 mL of BHI under anaerobiosis of 37°C for 48 h. Then, they were seeded with sterile swab in triplicate in the Mitis salivarius - Bacitracin culture medium. The samples were kept under anaerobiosis of 37°C for 48 h. Scores were used to count the number of colony forming units (cfu). The results were submitted to the Mann-Whitney statistical test at 5 percent significance level. RESULTS: There was statistically significant difference (p<0.05) for the reduction of bristle contamination comparing groups II, III, IV and V to group I. CONCLUSIONS: It may be stated that after toothbrushing, the Aloe vera and propolis dentifrice reduced the contamination of toothbrush bristles by SM, without differentiation from the other chemical agents used.


Subject(s)
Animals , Cattle , Aloe , Dentifrices , Dental Devices, Home Care/microbiology , Propolis , Streptococcus mutans , Sterilization/methods , Toothbrushing/instrumentation , Colony Count, Microbial , Culture Media , Random Allocation , Stem Cells , Streptococcus mutans/growth & development , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL